All Fox Products

METER TYPE/
LINE SIZE
Insertion: 1.5" - 70"
Insertion: 1.5" - 70"
Inline (w/flow conditioners): ¼" - 6"
Remote sensor mounting optional
Insertion: 1.5" - 70"
Inline (w/flow conditioners): ¼" - 6"
Remote sensor mounting optional
Insertion: 1.5" - 70"
Insertion: 1.5" - 70"
Inline (w/flow conditioners): 1.5" - 6"
Remote sensor mounting optional
OUTPUTS
USB Port;
4-20mA;
Selection of one 2nd output:
  • Pulse
  • Communication Options
USB Port;
2 X 4-20mA;
Pulse;
Communication Options
USB Port;
2 X 4-20mA;
Pulse;
Communication Options
USB Port;
4-20mA;
Selection of one 2nd output:
  • Pulse
  • Communication Options
USB Port;
2 X 4-20mA;
Pulse;
Communication Options
COMMUNICATION OPTIONS
RS485 Modbus RTU;
BACnet MS/TP; HART
RS485 Modbus RTU;
BACnet MS/TP;
Profibus-DP;
DeviceNet;
Ethernet Modbus TCP
RS485 Modbus RTU;
HART
RS485 Modbus RTU;
HART
RS485 Modbus RTU;
HART
CONTACT OR DISCRETE I/O
Discrete output for alarms*
Discrete output for alarms*
Contact input to reset total
Discrete output for alarms*
Contact input to reset total
Discrete output for alarms*
Discrete output for alarms*
Contact input to reset total
DATA LOGGER
None
None
Optional; with date/time stamp
None
Standard Data Logger with 40 24-hour totals &alarm/event logs with date/time stamp
Click here to read more
CALIBRATION VALIDATION (in-situ verification)
Zero CAL-CHECK®
None
CAL-V™
Zero CAL-CHECK®
CAL-V™
CAL-V™
POWER
10-30VDC
24VDC ±10%
85-264VAC
24VDC ±10%
85-264VAC
10-30VDC
10-30VDC
DISPLAY
(Optional)
2-Lines x 16 characters
Backlit
(Standard)
2-Lines x 16 characters
Backlit
(Optional)
2-Lines x 16 characters
Backlit
Infrared buttons
(Optional)
2-Lines x 16 characters
Backlit
(Optional)
2-Lines x 16 characters
Backlit
GAS SELECT MENU
Pure Gas Menu (11)
Mixed Gases (Mix 5)
None
None
Pure gas Menu (11)
Mixed Gas Menu (any of 11)
O&G Menu (any of 12)
Pure gas Menu (11)
Mixed Gas Menu (any of 11)
O&G Menu (any of 12)
GAS/GAS MIXES
Air
Argon
Butane
Carbon Dioxide
Helium
Click here for more gas options**
Dry pure gases,
Gas mixes (gas composition analysis must be submitted for factory calibration)
Dry pure gases,
Gas mixes (gas composition analysis must be submitted for factory calibration)
Air
Argon
Butane
Carbon Dioxide
Helium
Click here for more gas options
Air
Argon
Butane
Carbon Dioxide
Helium
Click here for more gas options
SENSOR
DDC-Sensor™
¾" probe
PowerPro™ Sensor
½" probe
PowerPro™ Sensor
½" probe
2nd Gen DDC-Sensor™
¾" probe
2nd Gen DDC-Sensor™
¾" probe
FREE SOFTWARE DOWNLOADS
Yes - FT1 View™
Yes - FT2A View™
Yes - FT3 View™
Yes - FT4A View™
Yes - FT4X View™
ACCURACY
±1% R ±0.5% FS (air)
±1.5% R ±0.5% FS (all other gases)
±1% R ±0.2% FS
±1% R ±0.2% FS
±1% R ±0.5% FS (air)
±1.5% R ±0.5% FS (all other gases)
±1% R ±0.5% FS (air)
±1.5% R ±0.5% FS (all other gases)
VELOCITY RANGE
0 - 15,000 SFPM;
0 - 71 NMPS
0 - 60,000 SFPM;
0 - 283 NMPS
0 - 60,000 SFPM;
0 - 283 NMPS
0 - 60,000 SFPM;
0 - 283NMPS
0 - 60,000 SFPM;
0 - 283NMPS
SENSOR TEMPERATURE RATINGS
-40° to 250°F (-40° to 121°C)
ST: -40° to 250°F (-40° to 121°C)
HT: -40° to 650°F (-40° to 343°C)
ST: -40° to 250°F (-40° to 121°C)
HT: -40° to 650°F (-40° to 343°C)
-40° to 250°F (-40° to 121°C)
-40° to 250°F (-40° to 121°C)
MAXIMUM PRESSURE
300 psig (20 barg)
500 psig (34 barg)
500 psig (34 barg)
500 psig (34 barg)
740 psig (51.02 barg)
APPROVALS
CE Mark***
FM/FMc Class I Div 1***
ATEX/IECEx Zone 1***
CE Mark***
FM/FMc Class I Div 2***
CE Mark***
FM/FMc Class I Div 1***
ATEX/IECEx Zone 1***
CE Mark***
FM/FMc Class I Div 1***
ATEX/IECEx Zone 1***
CE Mark***
FM/FMc Class I Div 1***
ATEX/IECEx Zone 1***
*Contact output in place of pulse
**Gas mix can contain any three of the gases listed for the FT1 in any proportion totaling 100%
**See Model Datasheets for more specific information on Approvals